Page #16 background image
E1SL 16 532258 04 - Rev. B
Translation of the original instructions
ENGLISH
6 BASIC Programming
BASIC Function Default: A1000 A1400 AIR RKE 1400 SF1400 GBF1500
CF
Automation model If this parameter is modified, the relative default configuration is loaded.
1 2 3 4 5
no = no selection (factory default)
1 = A1000
2 = A1400 AIR
3 = RKE 1400 (for SLIDING FHE )
4 = SF1400
5 = GBF1500
dF
DEFAULT configuration Indicates whether the programming corresponds to the default settings for the
automation model and allows you to reload the defaults.
no = at least 1 parameter has been modified. If you wish to reload the default values, select Y
Y
= programming corresponds to the default settings
YY YYY
Ln
Leaf number - displayed only for SF1400 (CF= 4) If modified you have to perform the SETUP.
1 = 1 leaf
2 = 2 leaves
-- -2-
Lt
Select passage opening - displayed only for SF1400 (CF= 4)
1 = narrow opening width: max 65 cm (with 1 leaf), max 130 cm (with 2 leaves)
2 = average opening width: 65…75 cm (with 1 leaf), 130…150 cm (with 2 leaves)
3 = wide opening width: greater than 75 cm (with 1 leaf), greater than 150 cm (with 2 leaves)
-- -2-
rM
Direction of rotation of the motor If it is modified you have to perform the SETUP.
1 = STANDARD rotation
-1 = NON STANDARD rotation
1 1 1 1 1
PO
Partial Open - NOT displayed for SF1400 (CF= 4) or for GBF1500 (CF= 5)
no = 100%
2095 % Adjustment step = 5%
50 50 50 - -
PA
Pause time before closing again in automatic operation mode
030 s Adjustment step = 1 s
22 222
ES
Energy Saving
no = not enabled
Y = enabled
no no no no no
Pn
Night pause time In Night mode, after being opened via the Key command, the door remains open for the
length of time set (
0 s … 4.0 min)
058 s Adjustment step = 2 s
1.04.0 min Adjustment step = 10 s (e.g. 1.2 = 1 min and 20 s)
10 10 10 10 10
cS
Closing speed
level
110
55 55 1
oS
Opening speed
level
110
10 8 8 5 3
cF
Closing force
level
110
55 555
oF
Opening force
level
110
88 1085
tF
Force time on obstacle for CF and OF
0.13.0 s Adjustment step = 0.1 s
1.0 1.0 2.0 1.0 1.0
dr
Deceleration ramp when OP and CL
level
110
66 645
Ar
Acceleration ramp when OP and CL
level
110
88 585

Table of Contents

Other manuals for FAAC SDK EVO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC SDK EVO and is the answer not in the manual?

FAAC SDK EVO Specifications

General IconGeneral
BrandFAAC
ModelSDK EVO
CategoryControl Unit
LanguageEnglish

Related product manuals