Figure 13-2 Universal Protocol Sengs
EPSON
The xed start and end line tag are used for EPSON protocol.
AVE
The
xed start and end line tag are used for AVE protocol. Serial port and virtual serial port
connecon types are supported.
Click Custom to congure the AVE sengs. Select Rule as VSI-ADD or VNET . Set the address
bit of the POS message to send. Click OK to save the
sengs.
NUCLEUS
Click the Custom to congure the NUCLEUS sengs.
Enter the employee No., shi No., and the terminal No. in the eld. The matching message
sent from the POS device will be used as the valid POS data.
Note
The NUCLEUS protocol must be used in the RS-232 connecon communicaon.
6. Select Connecon Mode and click Parameters to congure the parameters for each connecon
mode.
TCP
Connecon
When using TCP connecon, the port must be set from 1 to 65535, and the port for each POS
machine must be unique.
Set the Allowed Remote IP Address of the device sending the POS message.
UDP
Connecon
When using UDP connecon, the port must be set from 1 to 65535, and the port for each
POS machine must be unique.
Set the Allowed Remote IP Address of the device sending the POS message.
Network Video Recorder User Manual