Operation Diagnosis
UM Basic Configuration L3P
Release
7.1
12/2011
9.1
Sending Traps
211
9.1.1 List of SNMP traps
The following table shows a list of the traps that can be sent by the device.
Trap name Meaning
authenticationFailure this is sent if a station attempts to access an agent without
authorisation.
coldStart this is sent during the boot phase for both cold starts and warm
starts, after successful initialisation of the network management.
hmAutoconfigAdapterTrap this is sent when the AutoConfiguration Adapter (ACA) is
disconnected or connected.
linkDown this is sent if the connection to a port is interrupted.
linkUp this is sent when connection is established to a port.
hmTemperature this is sent if the temperature exceeds the set threshold limits.
hmPowerSupply this is sent if the power supply status changes.
hmSigConRelayChange this is sent if the status of the signal contact changes in the
function monitoring.
newRoot this is sent if the sending agent becomes the new root of the
spanning tree.
topologyChange this is sent if the switching mode of a port changes.
risingAlarm this is sent if an RMON alarm input exceeds its upper threshold.
fallingAlarm this is sent if an RMON alarm input goes below its lower threshold.
hmPortSecurityTrap this is sent if an MAC/IP address detected on this port does not
correspond to the current settings for
– hmPortSecPermission and
– hmPorSecAction is set to either trapOnly (2) or portDisable (3).
hmModuleMapChange this is sent if the hardware configuration changes.
hmBPDUGuardTrap this is sent if a BPDU is received on a port while the BPDU Guard
function is active.
hmMrpReconfig this is sent if the configuration of the MRP Ring changes.
hmRingRedReconfig this is sent if the configuration of the HIPER Ring changes.
hmRingRedCplReconfig this is sent if the configuration of the redundant ring/network
coupling changes.
hmSNTPTrap this is sent if an error occurs in relation to the SNTP (e.g. server
not available).
hmRelayDuplicateTrap this is sent if a duplicate IP address is detected in relation to DHCP
Option 82.
lldpRemTablesChangeTra
p
this is sent if an entry in the Remote Table topology changes.
vrrpTrapNewMaster this is sent if another router becomes the master router for an
interface or a virtual address.
vrrpTrapAuthFailure this is sent if the router receives a packet with an invalid
authentication from another VRRP router.
hmConfigurationSavedTra
p
this is sent after the device has successfully saved its
configuration locally.
Table 25: Possible traps

Table of Contents

Other manuals for Hirschmann PowerMICE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann PowerMICE and is the answer not in the manual?

Hirschmann PowerMICE Specifications

General IconGeneral
BrandHirschmann
ModelPowerMICE
CategoryNetwork Router
LanguageEnglish

Related product manuals