EasyManuals Logo
Home>Hirschmann>Network Router>PowerMICE

Hirschmann PowerMICE User Manual

Hirschmann PowerMICE
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #220 background imageLoading...
Page #220 background image
Operation Diagnosis
220
9.3
Out-of-band Signaling
UM Basic Configuration L3P
Release
7.1
12/2011
9.3.3 Monitoring the Device Functions via the
Signal Contact
Configuring the operation monitoring
Displaying the signal contact’s status
The device gives you 3 additional options for displaying the status of the
signal contact:
LED display on device,
display in the Web-based interface,
query in the Command Line Interface.
Select the Diagnostics:Signal Contact dialog.
Select "Monitoring correct operation" in the "Mode signal contact"
frame to use the contact for operation monitoring.
In the "Monitoring correct operation" frame, you select the events
you want to monitor.
To monitor the temperature, you set the temperature thresholds in
the Basics:System dialog at the end of the system data.
enable Switch to the privileged EXEC mode.
configure
Switch to the Configuration mode.
signal-contact 1 monitor all Includes all the possible events in the operation
monitoring.
signal-contact 1 trap enable Enables a trap to be sent if the status of the
operation monitoring changes.

Table of Contents

Other manuals for Hirschmann PowerMICE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann PowerMICE and is the answer not in the manual?

Hirschmann PowerMICE Specifications

General IconGeneral
BrandHirschmann
ModelPowerMICE
CategoryNetwork Router
LanguageEnglish

Related product manuals