4.1 Loading the Software
manually from the ACA
You can connect the AutoConfiguration Adapter (ACA) to a USB port of your
PC like a conventional USB stick and copy the device software into the main
directory of the ACA.
Copy the device software from your computer to the ACA.
Now connect the ACA to the device‘s USB port.
Open the system monitor (see page 16 “Opening the system monitor”).
Select 2 and press the Enter key to copy the software from the ACA into
the local memory of the device.
At the end of the update, the system monitor asks you to press any key to
continue.
Select 3 to start the new software on the device.
The system monitor offers you additional options in connection with the
software on your device:
selecting the software to be loaded
starting the software
performing a cold start