l The LBG-2 bridge chip provides two GE electrical LOM ports, and two 10GE optical
LOM ports or two 10GE electrical LOM ports (through the X557 PHY).
l The Huawei Hi1710 management chip provides a VGA port, management network port,
and debugging serial port.
A.2 RAS Features
Table A-1 describes the reliability, availability, and serviceability (RAS) features supported
by the 2288H V5. You can configure these features for better performance.
NOTE
For details about how to configure these features, see the Huawei Server Purley Platform BIOS
Parameter Reference.
Table A-1 RAS features
Mod
ule
Feature Description
CPU Corrected Machine
Check Interrupt
Corrects error-triggered interrupts.
DIM
M
Failed DIMM Isolation Identifies a faulty DIMM and isolates it from others
before it is replaced.
Memory Thermal
Throttling
Automatically adjusts DIMM temperatures to avoid
damage due to overheating.
Rank Sparing Allocates some memory ranks as backup ranks to
prevent the system from crashing due to uncorrectable
errors.
Memory Address Parity
Protection
Detects memory command and address errors.
Memory Demand and
Patrol Scrubbing
Corrects errors upon detection. If these errors are not
corrected promptly, uncorrectable errors may occur.
Memory Mirroring Improves system reliability.
Single Device Data
Correction
Provides a single-device multi-bit error correction
capability to improve memory reliability.
Device Tagging Degrades and rectifies DIMM device faults to improve
DIMM availability.
Data Scrambling Optimizes data stream distribution and reduces the
error possibility to improve the reliability of data
streams in the memory and the capability to detect
address errors.
PCIe PCIe Advanced Error
Reporting
Improves server serviceability.
2288H V5 Server
User Guide
A Appendix
Issue 04 (2018-09-04) Copyright © Huawei Technologies Co., Ltd. 279

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei 2288H V5 and is the answer not in the manual?

Huawei 2288H V5 Specifications

General IconGeneral
BrandHuawei
Model2288H V5
CategoryServer
LanguageEnglish

Related product manuals