3 Basic Operations
3.1 Powering On the Server
3.2 Powering Off the Server
3.3 Removing the Server and Guide Rails
3.4 Removing the Chassis Cover
3.5 Installing the Chassis Cover
3.6 Removing a Fan Module
3.7 Removing Cables from a PSU
3.8 Removing the Air Duct
3.9 Installing the Air Duct
3.10 Removing the Built-in Drive Assembly
3.11 Installing the Built-in Drive Assembly
3.12 Removing a Riser Card Tray
3.13 Installing a Riser Card Tray
3.1 Powering On the Server
Power on the server using one of the following methods based on the actual situation:
l If the PSUs are properly installed but are not connected to an external power supply,
power on the server as follows:
Connect the external power supply to the PSUs. Then the server will power on with the
PSUs.
NOTE
The default value of System State Upon Power Supply is Power on, which indicates that the
server automatically powers on after power is supplied to the PSUs. To change the value of
System State Upon Power Supply, log in to the iBMC WebUI and choose Power > Power
Control.
2288H V5 Server
User Guide
3 Basic Operations
Issue 04 (2018-09-04) Copyright © Huawei Technologies Co., Ltd. 40