5 User Management
Quidway NetEngine20/20E
Configuration Guide - Basic Configurations
5-6 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 05 (2010-01-30)
No. Procedure
9 Configuring the Maximum Number of VTY User Interfaces
10 Configuring the Authentication Timeout Time for VTY Users
11 Disconnecting a Specified User Interface
12 Checking the Configuration
You can configure one or more user interfaces simultaneously in any view.
5.2.2 Transmitting Messages Between User Interfaces
Do as follows on the router that the user logs in to:
Run:
send { all | ui-number | ui-type ui-number1 }
The message is transmitted between the user interfaces.
5.2.3 Configuring Asynchronous Interface Attributes
Do as follows on the router that the user logs in to:
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
user-interface [ ui-type ] first-ui-number [ last-ui-number ]
The user interface view is displayed.
Step 3 Run:
speed speed-value
The transmission rate is set.
Step 4 Run:
flow-control { hardware | none | software }
The flow control mode is set.
Step 5 Run:
parity { even | mark | none | odd | space }
The parity mode is set.
Step 6 Run:
stopbits { 1.5 | 1 | 2 }

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway NetEngine 20 series and is the answer not in the manual?

Huawei Quidway NetEngine 20 series Specifications

General IconGeneral
BrandHuawei
ModelQuidway NetEngine 20 series
CategoryNetwork Router
LanguageEnglish

Related product manuals