EasyManuals Logo

Inovance IS620PT012I User Manual

Inovance IS620PT012I
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
IS620P User Manual Chapter 7 Function Code Table
- 181 -
Function
Code
Parameter
Name
Setting Range Unit Default
Effective
Time
Property
Control
Mode
H08 18
Speed
feedforward
lter time
constant
0.00–64.00 ms 0 Immediate
During
running
P
H08 19
Speed
feedforward
gain
0.0–100.0 % 0 Immediate
During
running
P
H08 20
Torque
feedforward
lter time
constant
0.00–64.00 ms 0.50 Immediate
During
running
P
H08 21
Torque
feedforward
gain
0.0–200.0 0.1 0 Immediate
During
running
P
H08 22
Speed
feedforward
lter
0: Disabled
1: Average lter of 2
speed feedbacks
2: Average lter of 4
speed feedbacks
3: Average lter of 8
speed feedbacks
4: Average lter of 16
speed feedbacks
- 0 Immediate At stop PS
H08 23
Cutoff
frequency
of speed
feedback
low-pass
lter
100–4000 Hz 4000 Immediate
During
running
PS
H08 24
PDFF control
coefcient
0.0–100.0 % 100.0 Immediate
During
running
PS
Group H09: Self-adjusting Parameters
Function
Code
Parameter Name Setting Range Unit Default
Effective
Time
Property
Control
Mode
H09 00
Auto-adjusting
mode
0: Disabled, manual
adjusting
1: Standard mode,
gain parameters
automatically
adjusted based on
rigidity table
2: Positioning mode,
gain parameters
automatically
adjusted based on
rigidity table
- 0 Immediate
During
running
PS

Table of Contents

Other manuals for Inovance IS620PT012I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS620PT012I and is the answer not in the manual?

Inovance IS620PT012I Specifications

General IconGeneral
BrandInovance
ModelIS620PT012I
CategoryServo Drives
LanguageEnglish

Related product manuals