Group H30: Servo Related Variables Read via Communication
The values are not displayed on the keypad.
Function
Code
Parameter Name Setting Range Unit Default
Effective
Time
Property
Control
Mode
H30 00
Servo state read via
communication
- - - -
Read-
only
PST
H30 01
DO function
state 1 read via
communication
- - - -
Read-
only
PST
H30 02
DO function
state 2 read via
communication
- - - -
Read-
only
PST
H30 03
Input reference
pulse sampling read
via communication
- - - - At display PST
Group H31: Servo Related Variables Set via Communication
The values are not displayed on the keypad.
Function
Code
Parameter Name Setting Range Unit Default
Effective
Time
Property
Control
Mode
H31 00
VDI virtual
level set via
communication
0–65535 - 0 Immediate
During
running
PST
H31 04
DO state set via
communication
0–31 - 0 Immediate
During
running
PST
H31 09
Speed
reference set via
communication
-6000 to 6000 rpm 0 Immediate
During
running
S
H31 11
Torque
reference set via
communication
-100.000 to
100.000%
% 0 Immediate
During
running
T

Table of Contents

Other manuals for Inovance IS620PT012I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS620PT012I and is the answer not in the manual?

Inovance IS620PT012I Specifications

General IconGeneral
BrandInovance
ModelIS620PT012I
CategoryServo Drives
LanguageEnglish

Related product manuals