6. Description of Parameters
- 111 -
6
6.2.2 Setting Auxiliary Frequency Reference
Auxiliary frequency reference has the same nine setting modes as main frequency reference
does.
F0-04 selects a proper channel to set auxiliary frequency reference.
Function Code Parameter Name Setting Range Default
F0-04
Auxiliary frequency
reference setting
channel selection
0: Digital setting (non-retentive at power down)
1: Digital setting (retentive at power down)
2: AI1
3: AI2
4: AI3
5: Pulse reference
6: Multi-reference
7: Simple PLC
8: PID reference
9: Serial comms.
0