6. Description of Parameters
- 158 -
6.8.4 Motor 2 Parameters
The drive supports driving two motors at different time. For the two motors, you can:
● Set motor nameplate parameters respectively
● Perform motor auto-tuning respectively
● Select V/F control or vector control respectively
● Set encoder-related parameters respectively
● Set parameters related to V/F control or vector control independently
Motor 2 parameters are defined the same as motor 1 parameters. For details on motor 1
parameters, see descriptions of these parameters in
6
.
4
M
o
t
o
r
A
u
t
o
-
t
u
n
i
n
g
.
You can select the desired motor parameter group in F0-24 or via a DI terminal
1. Select the desired motor parameter group in F0-24.
Function Code Parameter Name Setting Range Default
F0-24
Motor parameter group
selection
0: Motor parameter group 1
1: Motor parameter group 2
0
2. Select the desired motor parameter group via a DI terminal.
Set any DI (F4-00 to F4-09) for function 41 "Motor selection". If the DI is inactive, motor
parameter group 1 is selected. If the DI is active, motor parameter group 2 is selected.
Function Code Parameter Name Setting Description
Any of F4-00 to F4-09 DIx function selection 41 Motor selection
● If any of F4-00 to F4-09 is set for function 41 “Motor selection”, DI terminal
overrides F0-24. If none of F4-00 to F4-09 is set for function 41 “Motor
selection”, motor selection is determined by F0-24.
● Switchover of two groups of motor parameters is prohibited during drive
running. Otherwise, the drive detects Err41.
Function
Code
Parameter Name Setting Range Default
A2-00
Motor type selection 0 to 1 0
A2-01
Rated motor power 0.1 to 1000.0 kW Model
dependent
A2-02
Rated motor voltage 1 to 2000 V Model
dependent
A2-03
Rated motor current 0.01 to 655.35 (AC drive power ≤ 55 kW)
0.1 to 6553.5 (AC drive power > 55 kW)
Model
dependent
A2-04
Rated motor frequency 0.01 to max. frequency Model
dependent
A2-05
Rated motor speed 1 to 65535 Model
dependent
A2-06
Stator resistance 0.001 to 65.535 (AC drive power ≤ 55 kW)
0.0001 to 6.5535 (AC drive power > 55 kW)
Auto-tuning
parameter
A2-07
Rotor resistance 0.001 to 65.535 (AC drive power ≤ 55 kW)
0.0001 to 6.5535 (AC drive power > 55 kW)
Auto-tuning
parameter