Protocols=Allow All
d. Click OK to save changes, and select Commit>Commit to apply the configuration
and other pending changes (if any).
4. To use the port on the Mini-PIM, you must also set security policies. Select the following
settings:
a. Select Configure>Security>Security Policy.
b. Select Global Options > Policy Options.
c. Set Policy Action: Default Policy Action=Permit-All.
d. Click OK to save changes, and select Commit>Commit to apply the configuration
and other pending changes (if any).
Using the CLI
To perform basic configuration for the 1-Port T1/E1 Mini-PIM (for the T1 interface) and to
configure network interfaces for the services gateway with the CLI:
1. Verify that the T1/E1 interface is installed on the device:
show chassis hardware
2. Verify the status of the interface:
show interfaces terse
3. Assign the port an IP address:
For T1 interfaces:
set interfaces t1-1/0/0 unit 0 family inet address interface address/destination prefix
For E1 interfaces:
set interfaces e1-1/0/0 unit 0 family inet address interface address/destination prefix
4. Add or select a security zone; for example, Trust:
For T1 interfaces:
set security zones security-zone trust interfaces t1-1/0/0.0 host-inbound-traffic
system-services all
For E1 interfaces:
set security zones security-zone trust interfaces e1-1/0/0.0 host-inbound-traffic
system-services all
5. Add or select security zones for host inbound traffic protocol options:
For T1 interfaces:
Copyright © 2017, Juniper Networks, Inc.74
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference