Section 11: TSP command reference Series 3700A System Switch/Multimeter Reference Manual
11-94 3700AS-901-01 Rev. D/June 2018
channel.setmode()
This function sets the mode of operation of a channel.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Instrument reset
Channel reset
Recall setup
Create configuration script
Save setup
Digital I/O: 0 (channel.MODE_INPUT)
Totalizer: 3
(channel.MODE_RISING_TTL_EDGE)
DAC: 49
(channel.MODE_PROTECT_VOLTAGE_1)
Usage
channel.setmode("channelList", mode)
channelList
String specifying the channels to set, using normal channel list syntax
mode
The value that sets the mode of operation for a channel; see Details
Details
Different channel types contain additional configurable settings. These settings are grouped together
by channel type as described in the following paragraphs.
For digital I/O channels, the mode indicates the direction of the channel (input or output). The
following modes are supported:
• channel.MODE_INPUT (default) or 0
• channel.MODE_OUTPUT or 1
• channel.MODE_PROTECT_OUTPUT or 3
For totalizer channels, the mode indicates the configuration of the channel (edge and reset). The
following modes are supported:
• channel.MODE_RISING_EDGE or 1
• channel.MODE_FALLING_EDGE or 0
• channel.MODE_RISING_TTL_EDGE (default) or 3
• channel.MODE_FALLING_TTL_EDGE or 2
• channel.MODE_RISING_EDGE_READ_RESET or 5
• channel.MODE_FALLING_EDGE_READ_RESET or 4
• channel.MODE_RISING_TTL_EDGE_READ_RESET or 7
• channel.MODE_FALLING_TTL_EDGE_READ_RESET or 6
For DAC channels, the mode indicates the output of the channel (function and range). The output is
switched off before any mode change is made, and remains off after the mode has changed. The
following modes are supported:
• channel.MODE_VOLTAGE_1 or 17
• channel.MODE_CURRENT_1 or 1
• channel.MODE_CURRENT_2 or 2
• channel.MODE_PROTECT_VOLTAGE_1 (default) or 49
• channel.MODE_PROTECT_CURRENT_1 or 33
• channel.MODE_PROTECT_CURRENT_2 or 34

Table of Contents

Other manuals for Keithley 3721-ST

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3721-ST and is the answer not in the manual?

Keithley 3721-ST Specifications

General IconGeneral
BrandKeithley
Model3721-ST
CategoryMultimeter
LanguageEnglish

Related product manuals