EasyManuals Logo
Home>Keithley>Measuring Instruments>Series 2600

Keithley Series 2600 User Manual

Keithley Series 2600
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
List of Illustrations
Section 1 General Information
Figure 1-1. Typical system configuration for applications. . .1-1
Section 2 Two-terminal Device Tests
Figure 2-1. Series 2600 two-wire connections
(local sensing) . . . . . . . . . . . . . . . . . . . . . . .2-1
Figure 2-2. Voltage coefficient test configuration . . . . . . .2-1
Figure 2-3. Test configuration for capacitor leakage test . . .2-3
Figure 2-4. Staircase sweep . . . . . . . . . . . . . . . . . .2-5
Figure 2-5. Test configuration for diode characterization. . .2-5
Figure 2-6. Program 3 results: Diode forward
characteristics . . . . . . . . . . . . . . . . . . . . . . .2-6
Section 3 Bipolar Transistor Tests
Figure 3-1. Test configuration for common-emitter tests . . 3-1
Figure 3-2. Program 4 results: Common-emitter
characteristics . . . . . . . . . . . . . . . . . . . . . . 3-3
Figure 3-3. Gummel plot test configuration. . . . . . . . . 3-4
Figure 3-4. Program 5 results: Gummel plot . . . . . . . . 3-5
Figure 3-5. Test configuration for current gain tests
using search method . . . . . . . . . . . . . . . . . . . 3-6
Figure 3-6. Test configuration for fast current gain tests . . 3-8
Figure 3-7. Configuration for I
CEO
tests . . . . . . . . . . . 3-11
Figure 3-8. Program 8 results: I
CEO
vs. V
CEO
. . . . . . . . . 3-12
Section 4 FET Tests
Figure 4-1. Test configuration for common-source tests . . 4-2
Figure 4-2. Program 9 results: Common-source
characteristics . . . . . . . . . . . . . . . . . . . . . . 4-3
Figure 4-3. Configuration for transductance tests . . . . . 4-4
Figure 4-4. Program 10 results: Transconductance vs. V
GS
. 4-5
Figure 4-5. Program 10 results: Transconductance vs. I
D
. . 4-5
Figure 4-6. Configuration for search method
threshold tests . . . . . . . . . . . . . . . . . . . . . . 4-6
Figure 4-7. Configuration for self-bias threshold tests . . . 4-8
Section 5 Using Substrate Bias
Figure 5-1. TSP-Link connections for two instruments . . . 5-1
Figure 5-2. TSP-Link instrument connections . . . . . . . . 5-2
Figure 5-3. Program 12 test configuration . . . . . . . . . 5-3
Figure 5-4. Program 12 typical results: I
SB
vs. V
GS
. . . . . 5-4
Figure 5-5. Program 13 test configuration. . . . . . . . . . 5-5
Figure 5-6. Program 13 typical results: Common-source
characteristics with substrate bias . . . . . . . . . . . . 5-6
Figure 5-7. Program 14 test configuration . . . . . . . . . . 5-8
Figure 5-8. Program 14 typical results: Common-emitter
characteristics with substrate bias . . . . . . . . . . . . 5-9
Section 6 High Power Tests
Figure 6-1. High current (SMUs in parallel). . . . . . . . . 6-1
Figure 6-2. High voltage (SMUs in series) . . . . . . . . . . 6-2
Appendix A Scripts

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley Series 2600 and is the answer not in the manual?

Keithley Series 2600 Specifications

General IconGeneral
BrandKeithley
ModelSeries 2600
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals