EasyManuals Logo

Kubota GL9000D-AU-B User Manual

Kubota GL9000D-AU-B
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #168 background imageLoading...
Page #168 background image
GENERATOR
GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
2-S23
[3] SERVICING
(1) Terminal Voltage for Each Part During Normal Periods (No-load Periods)
Output Terminal
1. With the MCB (1) and RCBO (2) in the ON position, measure the
voltage in each phase and each line.
2. If the factory specification is not indicated, inspect the output
circuit or the wiring harness.
(Refer to 2-M16.)
9Y1211607GRS0030US0
(2) Stator Coil
Main Coil Winding
1. Test for continuity between coil leads with a milliohm meter.
Many kind of wiring have been arranged in the stator depending
on the voltage variation.
2. If the resistance is not as specified, replace the stator or contact
service station.
(Refer to 2-M16.)
* Measurement is not possible with a regular tester.
9Y1211607GRS0031US0
Detecting Coil
1. Measure the coil resistance between each auxiliary winding.
2. If the factory specification is not indicated, replace the stator or
contact service station.
(Refer to 2-M16.)
9Y1211607GRS0032US0
Output voltage Factory specification Rated voltage 7 or 8 %
(1) MCB (Miniature Circuit Breaker) (2) RCBO
(Residual Current Circuit Breaker)
Resistance Factory specification Refer to 2-S8.
[A] GL6000A-AU-B, GL6000D-AU-B [B] GL9000A-AU-B, GL9000D-AU-B
Resistance Factory specification Refer to 2-S8.
[A] GL6000A-AU-B, GL6000D-AU-B [B] GL9000A-AU-B, GL9000D-AU-B
KiSC issued 06, 2016 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota GL9000D-AU-B and is the answer not in the manual?

Kubota GL9000D-AU-B Specifications

General IconGeneral
BrandKubota
ModelGL9000D-AU-B
CategoryPortable Generator
LanguageEnglish

Related product manuals