COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
Model FA5000
Rev. 03 Page 212
Feb. 27/13
FDR Function Testing & Fault Isolation
23–7040
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Scroll
Arrow
Figure 203. Recorder Automatic Test Information PopUp Screen
NOTE: The User can select one of two test duration options; however
for this test procedure, use only the Single Pass Test Option.
Single Pass Test monitor data and dump data will be quickly
verified in one test pass.
Single Pass Test for XX hours and XX minutes monitor
data will be quickly verified, then data will be recorded for the
specified number of hours and minutes and then dumped and
verified.
Full Memory Test monitor data will be quickly verified, then
data will be recorded to fill memory and then dumped and veri-
fied. This test will take from 12 to 16 hours to complete.
(7) Observe in the window the following status messages as the test progresses:
Starting automatic test monitor data verification pass 1.
Successful completion of monitor data verification.
Starting data dump comparison testing.
The document reference is online, please check the correspondence between the online documentation and the printed version.

Table of Contents

Other manuals for L3 FA5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the L3 FA5000 and is the answer not in the manual?

L3 FA5000 Specifications

General IconGeneral
BrandL3
ModelFA5000
CategoryVoice Recorder
LanguageEnglish

Related product manuals