Page #101 background image
Diagnoscs and fault eliminaon
LED status display
"RDY" LED (blue) "ERR" LED (red) Status/meaning
O O Supply voltage not available.
On On
Inialisaon in progress (inverter is being started.)
Blinks (1 Hz)
O
Safe torque o (STO) acve. The inverter has been inhibited by the integrated safety
system.
Blinks (1 Hz) On
Inverter inhibited, error acve.
On
O
Inverter enabled.
Motor rotates according to the specied setpoint or quick stop is acve.
Both LEDs are blinking in a rapidly
alternang mode
Firmware update acve.
Both LEDs are blinking in a very rapidly
synchronous mode
"Visual tracking" funcon is acve.
Diagnosc interfaces
Depending on the purchase order, the inverter will include a connected keypad or a WLAN module.
Further informaon on the diagnosc modules can be found here: Download
A connecon to the WLAN module is established using the connecon data.
Connecon data (default sengs)
IP address 192.168.178.1
SSID «Product type»_«10-character idencaon code»
Password password
Diagnoscs and fault eliminaon
LED status display
101

Table of Contents

Other manuals for Lenze i550 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i550 Series and is the answer not in the manual?

Lenze i550 Series Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Overload Capacity150% for 60 seconds
Control TypeVector control
Communication InterfacesCANopen, Modbus, Ethernet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Frequency Range0 Hz
Cooling MethodAir cooling
Storage Temperature Range-25°C to +70°C
Input Voltage Range3-phase 380...480 V AC -15%/+10%