Technical data
Standards and operang condions
Conformies and approvals
Conformity
CE
2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TR CU 004/2011 Eurasian conformity: Safety of low voltage equipment
TR CU 020/2011
Eurasian conformity: Electromagnec compability of
technical means
RoHS 2011/65/EU
Restricons on the use of certain hazardous substances in
electrical and electronic devices
Approval
UL UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No.
274)
File No. E132659
Protecon of persons and device protecon
Degree of protecon
IP31
IP66
EN 60529
Informaon applies for completely and correctly installed
device.
NEMA Type 1
NEMA Type 4X outdoor
NEMA 250
UL Type 1
UL Type 4X outdoor
UL 50
UL 50E
Insulaon resistance
Overvoltage category III EN 61800-5-1 0 … 2000 m amsl
Overvoltage category II EN 61800-5-1 over 2000 m amsl
Isolaon of control circuits
Safe mains isolaon via double/reinforced
insulaon
EN 61800-5-1
Protecve measures against
Short circuit
Earth fault Earth-fault protected depending on operang status
Overtemperature of motor PTC or thermal contact, I²xt monitoring
Overvoltage
Motor stalling
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Please observe regulaons and safety instrucons!
Inrush current
≤ 3 x rated mains current
EMC data
Operaon on public supply systems
Take measures to limit the expected radio
interference:
The machine or system manufacturer is responsible for
compliance with the requirements for the machine/system!
< 1 kW: With mains choke
EN 61000-3-2
> 1 kW for mains current ≤ 16 A: Without
addional measures
Mains current > 16 A: With mains choke
or mains lter, with dimensioning for
rated power.
EN 61000-3-12
Noise emission
Category C1 EN 61800-3 See rated data
Category C2 EN 61800-3 See rated data
Category C3 EN 61800-3 See rated data
Noise immunity
Fullls requirements according to EN 61800-3
Technical data
EMC data
102