EtherCAT
Notes on the EtherCAT connecon status and the data transfer can be obtained via the LED "L/A" at the RJ45
sockets.
LED "L/A"
Blinking paern State Meaning
o Not connected Network not available
on
Connected Network available
No data transfer
blinking
Trac Data transfer
Typical topologies
Line
IN OUT
M
R
SDn
SD2
SD1
IN OUT IN
M Master
SD Slave Device
Bus-related informaon
Name EtherCAT
Communicaon medium Ethernet 100 Mbps, full duplex
Use Connected as EtherCAT slave
Status display 2 LEDs (RUN, ERR)
Basic network sengs
The rotary encoder switch allows you to set an EtherCAT idener.
x16
x1
Seng Idener
0x00 Value from parameter
0x01 ... 0xFF Switch posion
Electrical installaon
Networks
EtherCAT
90

Table of Contents

Other manuals for Lenze i550 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i550 Series and is the answer not in the manual?

Lenze i550 Series Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Overload Capacity150% for 60 seconds
Control TypeVector control
Communication InterfacesCANopen, Modbus, Ethernet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Frequency Range0 Hz
Cooling MethodAir cooling
Storage Temperature Range-25°C to +70°C
Input Voltage Range3-phase 380...480 V AC -15%/+10%