7. POSITIONING CONTROL
7 − 11
7.1.6 Stop processing and restarting after a stop
This section describes the stop processing after a stop cause is input during
positioning, and restarting after a stop.
(1) Stop processing
(a) Stop processing methods
Stop processing during positioning depends on the type of stop cause which
was input.
1) Deceleration stop........
(Process 1)
Decelerates and stops according to the stop
deceleration time parameter in the parameter block.
Parameter (Speed limit value)
Operation speed
Stop cause
Stop
Actual deceleration time
Stop deceleration time in
the parameter block
2) Rapid stop...................
(Process 2)
Decelerates and stops according to the rapid stop
deceleration time parameter in the parameter block.
Stop cause
Stop
Actual deceleration time
Rapid stop deceleration
time in the parameter block

Table of Contents