Page #51 background imageLoading...
Page #51 background image
4.2
About Functions
-
Functions and overall procedures
I
Generation of new programs
I
Use the TP keys
to
write programs and parameters to the RAM memory built in the TP to execute
reading, correcting, (inserting, deleting, rewriting), verifying, etc.
Changing existing programs
After reading programs from the FX-EEPROM-4 cassette mounted onto the PGU or from the CMT
(audio cassette recorder) to the TP, execute corrections and verification checks as necessary.
Transferring to the PGU for execution
After writing programs from the RAM built
in
the TP to the FX-EEPROM-4 ROM cassette of the PGU,
perform test operations as necessary.
I
Storing programs
I
Programs and parameters in the FX-EEPROM-4 ROM cassette can be stored in the PGU instead of
the CMT tape cassette or the TP's RAM memory.
Mode and function directory
All
functions (unless otherwise specified) are valid in the MANUAL and AUTO modes.
insertion
PROGRAM
I
53
I
Reference
PARAMETER
121
.....................
. .
, ,
. . .
.
.
. . .
.
. .
. .
.
DELETE
Program
deletion
50, 53
>ASSETTE
dAGNETlC TAPE
1-1-1
I
-
:ENTRAL
'ROCESSING
UNIT
READ
Program
reading/
display
52, 53
Parameter
reading/
display
55
TP
7
Read
CMT
63
TP
7
Read
PG U
58
WRITE
Program
writing/
rewriting
51, 53
Parameter
rewriting
55
TP
1
Write
CMT
63
TP
-
PGU
Write
MANUAL
(PROTECT-OFF)
57
I
Program
:hecking
-
54
-
Parameter
Zhecking
-
TP
f
4
Verify
ZMT
64
TP
r~~~
test
PGU
opera-
Verify
(PROTECT-OFF)
STOP key PGU
MANUAL tion monitor
valid
58
60
to
62 59
F
(1)
Home position return function
(5)
Error reset function (See error code pages
108
to
1
10.)
(2)
PGU,
TP
program simultaneous rewrite function
(6)
Fixed length feed function
(3)
PGU, TP parameter simultaneous rewrite function
JOG
+,
JOG
-,
STOP keys also valid.
(4)
Register rewrite function
~~~ ~ ~ ~
CPU TST Functions
7
J
-49-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-F FX-1GM and is the answer not in the manual?

Mitsubishi MELSEC-F FX-1GM Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-F FX-1GM
CategoryControl Unit
LanguageEnglish

Related product manuals