Eye sensor inspection and adjustment
Caution:
When this adjustment software is used for the rst time, prepare three units of D60, and get the reference values
of the eye sensor for the main menu.
Move the camera closer to the standard reector. Measure the distance where TFT monitor blacks out and input
the average value of the three cameras.
Move the camera away from the standard reector. Measure the distance where TFT monitor lights up and input
the average value of the three cameras.
D60
Standard reector (10cm×10cm)
※
Input the value into the screen for getting reference values of the eye sensor.
△ (Addition)
Reference line (Eye-sensor) face
△ (Addition)
Only (J18360) is available.