- A 0 ・ -
logo_Q0650_forGraphic
071004_Gdesign_ito
VBA21001-R.3753.A
(5) Sensitivity ratio adjustment
・Click "Start".
・Setting conditions are displayed.
・Attach the tool lens (Aperture F5.6) (without lter).
・Get the camera closest to the center of the illuminated surface of the shutter tester (LV9).
・Click "OK".
・The adjustment starts. When it is completed, the next setting conditions are displayed.
・Attach the tool lens (Aperture F5.6) and ND lter (ND8×1).
・Get the camera closest to the center of the illuminated surface of the color viewer.
・Click "OK".
・The adjustment starts. When it is completed, "OK" is displayed.
・Click "OK".
・Click "Next".
(6) Image shutter inspection and adjustment
・Click "Start".
・Setting conditions are displayed.
・Attach the tool lens (Aperture F5.6).
・Get the camera closest to the center of the illuminated surface of the shutter tester (LV9).
・Click "OK".
・The adjustment starts. When it is completed, the next setting conditions are displayed.
・Attach the tool lens (Aperture F5.6).
・Get the camera closest to the center of the illuminated surface of the shutter tester (LV15).
・Click "OK".
・The adjustment starts. When it is completed, "OK" is displayed.
・Click "OK".
・Click "Next".
7-2. Pixel defect compensation - black point
・Click "Start".
・Setting conditions are displayed.
・Attach the tool lens (Aperture F5.6).
・Get the camera closest to the center of the illuminated surface of the color viewer.
・Click "OK".
・The adjustment starts. When it is completed, "OK" is displayed.
・Click "OK".
・Click "Next".
*
Note: In some cases, NG occurs due to dusts on the CCD.
Be sure to clean the CCD surface before adjustments.