Applications 4
Pulse Laser Station NPL-302 Series Instruction Manual 101
Measuring distance and offset values on the slope 40.1
1. To enter the 3-Pt Reference Plane function,
press
[7] or select
S-Plane in the Programs menu.
2. Enter three points to define the slope plane. To
enter the point by direct measurement, press
the
MSR softkey.
If you press
[ENT] in a blank field, an input
screen for temporary coordinates appears.
These coordinates will not be stored.
When you have entered the temporary
coordinates,
<Keyed-in XYZ> appears
instead of the PT name.
Stn
P2
(X
2
,Y
2
,Z
2
)
P1
(X
1
,Y
1
,Z
1
)
P3
(X
3
,Y
3
,Z
3
)
Target
(X,Y,Z)
b
a

Table of Contents