AFP-2800 - Fire Indicator Panel – Panel Operation Page 15
©
N
OTIFIER
I
NERTIA
P
TY
L
TD
,
2001
WWW
.
INERTIA
.
COM
.
AU
4
44
4
4
44
4
.
..
.
.
..
.
1
11
1
1
11
1
.
..
.
.
..
.
2
22
2
2
22
2
E
EE
E
E
EE
E
N
NN
N
N
NN
N
T
TT
T
T
TT
T
E
EE
E
E
EE
E
R
RR
R
R
RR
R
I
II
I
I
II
I
N
NN
N
N
NN
N
G
GG
G
G
GG
G
I
II
I
I
II
I
N
NN
N
N
NN
N
F
FF
F
F
FF
F
O
OO
O
O
OO
O
R
RR
R
R
RR
R
M
MM
M
M
MM
M
A
AA
A
A
AA
A
T
TT
T
T
TT
T
I
II
I
I
II
I
O
OO
O
O
OO
O
N
NN
N
N
NN
N
On screens where character information needs to be entered, such as point labels, this must be done using an
external QWERTY style keyboard plugged into the PS2 keyboard plug on the rear of the CPU panel.
On screens (e.g. menus, change time/date) that require only numbers to be entered, can be entered directly with
the ten digit numeric keypad.
4
44
4
4
44
4
.
..
.
.
..
.
1
11
1
1
11
1
.
..
.
.
..
.
3
33
3
3
33
3
S
SS
S
S
SS
S
Y
YY
Y
Y
YY
Y
S
SS
S
S
SS
S
T
TT
T
T
TT
T
E
EE
E
E
EE
E
M
MM
M
M
MM
M
C
CC
C
C
CC
C
O
OO
O
O
OO
O
U
UU
U
U
UU
U
N
NN
N
N
NN
N
T
TT
T
T
TT
T
E
EE
E
E
EE
E
R
RR
R
R
RR
R
S
SS
S
S
SS
S
On the top right hand side of all screens are the system counters showing the total number of
alarms, faults, isolates and non-alarm (supervisory) events on the system at any time. If a
device is both isolated and in fault it will increment both counters. For more information as to
which points are isolated, refer to the list menus.
4
44
4
4
44
4
.
..
.
.
..
.
1
11
1
1
11
1
.
..
.
.
..
.
4
44
4
4
44
4
P
PP
P
P
PP
P
O
OO
O
O
OO
O
I
II
I
I
II
I
N
NN
N
N
NN
N
T
TT
T
T
TT
T
F
FF
F
F
FF
F
O
OO
O
O
OO
O
R
RR
R
R
RR
R
M
MM
M
M
MM
M
A
AA
A
A
AA
A
T
TT
T
T
TT
T
S
SS
S
S
SS
S
As the system is a database, all distributed points on field modules are controlled and referred to in “Ring, Module,
I/O format”. ie: Ring.Module.I/O - where I/O can consist of input, output or AZF.
Examples are as follows.
Point to be referred to Syntax
Ring 1, Module 1, Output 1
1.1.o1.
Ring 1, Module 20, AZF input 1
1.20.Z1
Ring 1, Module 30, input 1
1.30.i1
Ring 1, Annunciator 1 (module 101), Output 1 (led #1)
1.101.o1
Ring 1, Annunciator 99 (module 199), Input 1 (button #1)
1.199.i1
FlashScan
Loop 1 Detector 1
L1D1
FlashScan
Loop 1 Module 1
L1M1
System points will be displayed and can be referred to as follows:
Description Syntax Comments
On Board AZF’s 2 AZF’s on termination Board
AZF #1 0.1.z1 (Ring 0 Module 1, zone 1)
AZF #2 0.1.z2 (Ring 0 Module 1, zone 2)
Distributed Field Modules Up to 99 modules per ring
AZF 1.1.z1 8 AZF points per AZM8 or PAZM8
module
Din 1.1.i1 3 Din Per SCS-8 Module
Dout 1.1.o1 4 Dout Per AZM-8, 3 Dout Per SCS-8
Annunciator Up to 99 Annunciators on ring 1
Inputs 1.101.i1 16 Din per 16AT, 24 Din Per SCS-8
Outputs 1.101.o1 32 Dout Per 16AT, 24 Dout Per SCS-8,
32 Dout Per ACM32A
FlashScan
Devices Up to 10 Loops
Detectors L1D1 159 Detectors Per Loop
Modules L1M1 159 Modules Per Loop
A = 2
F = 5
I = 10
N = 5
www.PDF-Zoo.com