Page 48 AFP-2800 - Fire Indicator Panel – Panel Operation
© N
OTIFIER
I
NERTIA
P
TY
L
TD
, 2001
WWW
.
INERTIA
.
COM
.
AU
4
44
4
4
44
4
.
..
.
.
..
.
3
33
3
3
33
3
.
..
.
.
..
.
6
66
6
6
66
6
S
SS
S
S
SS
S
E
EE
E
E
EE
E
R
RR
R
R
RR
R
V
VV
V
V
VV
V
I
II
I
I
II
I
C
CC
C
C
CC
C
E
EE
E
E
EE
E
M
MM
M
M
MM
M
E
EE
E
E
EE
E
N
NN
N
N
NN
N
U
UU
U
U
UU
U
–
––
–
–
––
–
F
FF
F
F
FF
F
L
LL
L
L
LL
L
A
AA
A
A
AA
A
S
SS
S
S
SS
S
H
HH
H
H
HH
H
S
SS
S
S
SS
S
C
CC
C
C
CC
C
A
AA
A
A
AA
A
N
NN
N
N
NN
N
Overview:
The AFP-2800 can support up to 10 loops of FlashScan
. Each loop can support 159 detectors and 159 modules.
On power up, the AFP-2800 programs the FlashScan
LCMs (Loop Control Modules) with the appropriate
information for devices installed, and then the LCMs handle all the polling of the devices. The LCMs report back to
the CPU only off normal conditions such as alarm, fault etc.
Therefore, if an LCM is for any reason powered down and re-powered, it must be re-programmed to be in sync
with the panel. The AFP-2800 detects disconnection / reconnection automatically and will re-program the LCM in
the background.
The LCM boards have a slave board that is called the LEM (loop expander module). Five (5) LCM/LEM pairs are
required to achieve 10 loops. Each LCM has an address switch to set the loop address for the pair. While it is not
mandatory that loops always be sequential it is highly recommended for ease of use.
Note: The FlashScan
menu option contains all functions specific to FlashScan
analog Addressable detectors and modules.
Many of these features can be accessed from previously explained list menus and instructions will not be duplicated here.
4.3.6.1
4.3.6.14.3.6.1
4.3.6.1 S
SS
S
ERVICE
ERVICE ERVICE
ERVICE
M
MM
M
ENU
ENU ENU
ENU
–
– –
– F
FF
F
LASH
LASHLASH
LASH
S
SS
S
CAN
CANCAN
CAN
– L
– L– L
– L
IST
ISTIST
IST
This menu option will list all 10 FlashScan
loops allowing the user to then select detectors or modules and
perform read status and/or change a point’s programming. For a full explanation, please refer to Service Menu -
List - on page 25
4.3.6.2
4.3.6.24.3.6.2
4.3.6.2 S
SS
S
ERVICE
ERVICE ERVICE
ERVICE
M
MM
M
ENU
ENU ENU
ENU
–
– –
– F
FF
F
LASH
LASHLASH
LASH
S
SS
S
CAN
CANCAN
CAN
– S
– S– S
– S
TATUS
TATUSTATUS
TATUS
This menu option gives direct access to the read status screen of a FlashScan
point.
You will be prompted for a Loop Number and a Detector or Module number.
You will then be taken directly to the Read Status screen for the point.
Please refer to Service Menu - List – FlashScan – Detectors - Status on page 27
Or Service Menu - List – FlashScan – Modules - Status on Page 30
4.3.6.3
4.3.6.34.3.6.3
4.3.6.3 S
SS
S
ERVICE
ERVICE ERVICE
ERVICE
M
MM
M
ENU
ENU ENU
ENU
–
– –
– F
FF
F
LASH
LASHLASH
LASH
S
SS
S
CAN
CANCAN
CAN
- P
- P- P
- P
ROGRAM
ROGRAMROGRAM
ROGRAM
This menu option is direct access to the program / change point screen of a FlashScan
point.
You will be prompted for a loop number and a detector or module number.
You will then be taken directly to the program / change point screen for the point.
Please refer to Service Menu - List – FlashScan – Detectors - Change on page 28
Or Service Menu - List – FlashScan – Modules - Change on page 32
www.PDF-Zoo.com