G-6
Programming Sheets & Glossary 15088:J 10/22/99
Glossary of Terms and Abbreviations
Alarm Verification - A method of reducing false alarms incorporating time delays up to 50 seconds in length.
APS-6R - Auxiliary Power Supply. Used to supply filtered, non-resettable power to compatible devices.
Central Station - Main AM2020/AFP1010 panel and any associated annunciators and printers.
Control-by-Event (CBE) Programming - A method of providing a variety of output responses based on various
initiating conditions (events).
Cooperative Control-by-Event (CCBE) Programming - A method of providing a variety of output responses on
the NOTIFIRENET network based on various initiating conditions.
Day/Night Sensitivity - A way to force intelligent detectors into high or low sensitivity using the High and/or Low
Sensitivity Zones.
Detector Sensitivity - The responsiveness of a detector to stimuli associated with fire (i.e. smoke, heat).
DIA - Display Interface Assembly (keypad, system status LEDs and the 80-character LCD).
Display Abbreviations:
LMD Local Mode Intelligent Detector Address
LMM Local Mode Monitor Module Address
LOZNDET Low Zone Day/Night Sensitivity
MDM TPI-232
MIBA MIB-W/WF Threshold Channel A
MIBB MIB-W Threshold Channel B
NAM NAM-232
NAR Non-Alarm Monitor Module Reporting
PAL Pre-Alarm
PEC Printer Error Continue (transmit)
PGR PAGE-1
PORTS MIB Data Port Usage
PTI Primary Printer Trouble Inhibit
RP Rapid Polling
RPT Reports Redirected to CRT
SER Security Monitor Module Reporting
SIL Signal Silence Inhibit
SL Status Line (CRT Terminal)
SUP Supervisory ACS Reporting
TS Terminal Supervision
UDACT Universal Digital Alarm
Communicator Transmitter
UPDN Upload/Download
VER Alarm Verification
XINT External Interface
ACK AL Acknowledged Alarm
ACK TB Acknowledged Trouble
ACL AL Acknowledged Clear Alarm
ACL TB Acknowledged Clear Trouble
ADDR ISIB NOTIFIRENET Address
APM Auxiliary Printer Monitoring
BC Bidirectional Copy
BCAP Battery Capacity
BLN Device Blink
BSBY Battery Standby Time
BTYP Battery Type
CLR AL Clear Alarm
CLR TB Clear Trouble
CMR Control Module Reporting
CUT Signal Cutout
DBID Database Identification
DFT Drift Compensation
DPZ Disabled Piezo
DVTCNTR Detector Verification Trouble Counter
Limit
ERM Event Reminder
HIZNDET High Zone Day/Night Sensitivity
ISIB Intelligent Serial Interface Board
LEDL LEDs latched on activated devices
LMC Local Mode Control Module Address
Download - To retrieve the system configuration program data from a file on an IBM PC (personal computer) and
store it permanently in the AM2020/AFP1010 system.
Drift Compensation - An algorithm which permits the maintenance of a constant smoke detector sensitivity by
accounting for environmental contaminants and other factors.
www.PDF-Zoo.com

Table of Contents

Other manuals for Notifier AFP1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier AFP1010 and is the answer not in the manual?

Notifier AFP1010 Specifications

General IconGeneral
BrandNotifier
ModelAFP1010
CategoryFire Alarms
LanguageEnglish

Related product manuals