EasyManuals Logo
Home>Omron>Touch terminals>NS - SETUP

Omron NS - SETUP User Manual

Omron NS - SETUP
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #282 background imageLoading...
Page #282 background image
Appendix 3 Using NS-AL002 Converters
A-22
A-3-2 Mounting and Removing
Connect the NS-AL002 directly to port A or port B of the PT. Two NS-AL002 Adapters
cannot be connected to ports A and B simultaneously.
Mount the Adapter by tightening and securing the mounting screws on both of the D-Sub
connectors. The correct tightening torque is 0.3 Nâ‹…m. The correct tightening torque for the
terminal block is 0.5 Nâ‹…m.
To remove the Adapter, loosen the screws and pull out the Adapter.
Precautions
for Safe Use
• Always turn OFF the power to the PT before removing the Adapter.
• Do not touch the surface or the mounted parts of the Board with bare hands.
Always discharge any static electricity from your body before handling the
Board.
Precautions
for Correct Use
• Mount to the PT after securely connecting the cable to the terminal block.
Be sure to tighten the mounting screws on both of the D-Sub connectors. If
the screws are loose, the FG terminals of the PT and NS-AL002 will not be
connected.
A-3-3 Specifications
The following table shows the general specifications and communications specifications
of the Adapter.
 General Specifications
Item Specifications
Dimensions
45 × 49 × 28.5 mm (W × H × D)
Weight 50 g max.
Ambient operating temperature
0 to 50°C
Storage temperature
−20 to 60°C
Ambient operating humidity 35% to 85% (without condensation)
Rated power supply
5 V ±10% (through pin 6 of the RS-232C connector)
Power consumption 150 mW max.
Operating environment No corrosive gases.
Vibration resistance Conforms to PT specifications.
Shock resistance Conforms to PT specifications.
Reference
NS-series RS-485 (two-wire) communications are used to connect to an OMRON
Temperature Controller. The NS-AL002 cannot be used with the NT-series PTs or
PLCs.
 Communications Specifications
• RS-422A Interface
Item Specifications
Baud rate 115.2 kbps max.
Transmission distance 500 m total length (See note 1.)
Terminal block format 8-terminal terminal block, M3.0
Insulation No insulation (See note 2.)
Note 1: This specification is for a configuration in which all the Adapters connected on the same
transmission path are NT-AL002 Link Adapters. If a CJ1W-CIF11 Conversion Adapter is
used, the total length is 50 m.
Note 2: The RS-422A and RS-232C are not insulated.