27 Unexpected attribute in list An attempt was made to set an attribute that is not
able to be set at this time.
28 Invalid Member ID The Member ID specified in the request does not
exist in the specified Class/Instance/Attribute.
29 Member not settable A request to modify a non-modifiable member was
received.
2A Group 2 only server general failure This error code may only be reported by DeviceNet
group 2 only servers with 4K or less code space
and only in place of Service not supported, Attri-
bute not supported and Attribute not settable.
2B-CF --- Reserved by CIP for future extensions
D0-FF Reserved for Object Class and service
errors
This range of error codes is to be used to indicate
Object Class specific errors. Use of this range
should only be performed when none of the Error
Codes presented in this table accurately reflect the
error that was encountered.
Example of Additional Status in Case That General Status is 01 Hex
(Status of Connection Manager Object)
General status
code (hex)
Additional status code (hex) Description
01 0100 Connection in Use or Duplicate Forward Open.
01 0103 Transport Class and Trigger combination not sup-
ported
01 0106 Ownership Conflict
01 0107 Connection not found at target application.
01 0108 Invalid Connection Type. Indicates a problem with
either the Connection Type or Priority of the Con-
nection.
01 0109 Invalid Connection Size
01 0110 Device not configured
01 0111 RPI not supported. May also indicate problem with
connection time-out multiplier, or production inhibit
time.
01 0113 Connection Manager cannot support any more
connections
01 0114 Either the Vendor Id or the Product Code in the key
segment did not match the device
01 0115 Product Type in the key segment did not match the
device
01 0116 Major or Minor Revision information in the key seg-
ment did not match the device
01 0117 Invalid Connection Point
01 0118 Invalid Configuration Format
01 0119 Connection request fails since there is no con-
trolling connection currently open.
01 011A Target Application cannot support any more con-
nections
01 011B RPI is smaller than the Production Inhibit Time.
01 0203 Connection cannot be closed since the connection
has timed out
General status
code (hex)
Status name Description

Table of Contents

Other manuals for Omron NX-EIC202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX-EIC202 and is the answer not in the manual?

Omron NX-EIC202 Specifications

General IconGeneral
BrandOmron
ModelNX-EIC202
CategoryController
LanguageEnglish

Related product manuals