EasyManuals Logo
Home>Omron>Controller>NX-EIC202

Omron NX-EIC202 User Manual

Omron NX-EIC202
430 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #379 background imageLoading...
Page #379 background image
A - 33
Appendices
NX-series EtherNet/IP Coupler Unit User’s Manual (W536)
A-1 Supported CIP Objects
A
A-1-7 Response Codes
01 0204 Unconnected Send timed out waiting for a
response.
01 0205 Parameter Error in Unconnected Send Service
01 0206 Message too large for Unconnected message ser-
vice
01 0207 Unconnected acknowledge without reply
01 0301 No buffer memory available
01 0302 Network Bandwidth not available for data
01 0303 No Tag filters available
01 0304 Not Configured to send real-time data
01 0311 Port specified in Port Segment Not Available
01 0312 Link Address specified in Port Segment Not Avail-
able
01 0315 Invalid Segment Type or Segment Value in Path
01 0316 Path and Connection not equal in close
01 0317 Either Segment not present or Encoded Value in
Network Segment is invalid.
01 0318 Link Address to Self Invalid
01 0319 Resources on Secondary Unavailable
01 031A Connection already established
01 031B Direct connection already established
01 031C Miscellaneous
01 031D Redundant connection mismatch
01 031F No connection resources exist for target path
01 0320-07FF Vendor specific
General status
code (hex)
Additional status code (hex) Description

Table of Contents