4 Determining IP Addresses
4-12
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
The current IP address can be confirmed in the Controller Status Pane of the Sysmac Studio either
when it is set manually or obtained from the BOOTP server.
Display when using the NJ-series CPU Unit and the NX1P2 CPU Unit
Display when using the NX701 CPU Unit
• If you obtain the IP address from the BOOTP server, you can check the obtained IP address
by synchronizing and uploading the controller settings from the Sysmac Studio.
• If the IP address of the built-in EtherNet/IP port is not registered due to the following reasons,
the IP address field shows “0.0.0.0”.
• The IP address was not obtained from the BOOTP server.
• The built-in EtherNet/IP port on an NX701 CPU Unit is set to disable. Refer to 5-1 TCP/IP
Settings Display.
Refer to 5-1 TCP/IP Settings Display for details on the setting the IP address of the built-in Ether-
Net/IP port.
4-2-4 Checking the Current IP Address
• Basic Controller Status Pane • Controller Status Pane with Details
• Basic Controller Status Pane • Controller Status Pane with Details