12 Automatic Clock Adjustment
12-4
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
12-2 Procedure to Use the Automatic
Clock Adjustment Function
1
Make the basic settings.
Refer to 1-5 EtherNet/IP Communications Procedures for the flow of basic operations.
2
Select Built-in EtherNet/IP Port Settings from the Controller Setup on the Sysmac Studio,
and then set the following on the NTP Settings Display.
• NTP server settings (required)
• NTP operation timing
3
Select Synchronization from the Controller Menu. The built-in EtherNet/IP port settings are
transferred to the CPU Unit.
The following Built-in EtherNet/IP Port Settings are made from the Sysmac Studio to use automatic
clock adjustment.
Additional Information
Make the settings in the NTP Settings Dialog Box if automatic clock adjustment is used. Refer to
5-4 NTP Settings Display for information on the NTP Settings Dialog Box.
*1 This setting is required to get the clock information from the NTP server.
*2 The following ports are used by the system and cannot be set by the user: 25, 53, 68, 110, 2222, 2223, 2224,
9600, and 44818.
12-2-1 Procedure
12-2-2 Settings Required for Automatic Clock Adjustment
Tab page Setting Setting conditions Reference
NTP NTP server clock information Required. page 5-8
Port No. Specified by user.
Note Required to change from the
default value of 123.
Server specifying method
Required
*1
IP address One of these must be set, depending on
the Server specification type setting.
Host name
NTP operation timing
Required
*1
Specify a Time One of these must be set. (Set according
to the option selected for the NTP Oper-
ation Timing.)
Specify a time inter-
val
Timeout time Specified by user.
Note Required to change from the
default value of 10 seconds.

Table of Contents

Other manuals for Omron Sysmac NJ-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Sysmac NJ-series and is the answer not in the manual?

Omron Sysmac NJ-series Specifications

General IconGeneral
BrandOmron
ModelSysmac NJ-series
CategoryComputer Hardware
LanguageEnglish

Related product manuals