© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 101
Message Out of Service Displayed
Description
Console is displaying a message that says Temporarily Out of Service. Please use another machine.
Possible Causes
1 Software has encountered an error causing the console to enter Out of Service mode
2 The Auto Stop sensor on a treadmill is missing, improperly installed, or malfunctioning (Treadmill
Only).
Possible Remedies
1 Reboot the console. Most issues causing Out of Service errors will be cleared from a reboot.
2 Treadmill Only. Inspect the Auto Stop sensor and ensure it is installed properly. Inspect Auto Stop
cable to ensure it is inserted properly and undamaged. Repair or replace if needed. OOS error will
clear as soon as the sensor is detected. Do not disable the Auto Stop sensor in the software. For more
trouble shooting information on the Auto Stop feature see Troubleshooting- TRM_ Trouble Shooting
the Auto Stop Feature.