© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 85
Boot Error resulting in Yellow Triangle Being Displayed
Description
When the P80 is powered on there is a small delay of 2.5 minutes caused by the various boards initializing
in a specific sequence. If there is a problem with the initialization of any of these, the P80 will attempt to
load that software from the backup software location. While the backup software is loading a progress bar
will be displayed, but if the attempt fails a red "X" will be displayed over the progress bar, and a 2nd
attempt will be made automatically. If it fails the second attempt, the yellow triangle screen will be
displayed.
Figure 61: Yellow Triangle Screen
Possible Causes
1 Second re-boot attempt failed resulting in a recoverable boot error.
Possible Remedies
1 Recovery from this error may be possible. Please call Precor Customer Support for assistance.