Touch Screen Responds Incorrectly to Touch or is Unresponsive
Description
Touch screen reads touches, but it is not registering them where the user is touching the screen.
Possible Causes
1 The touch screen was improperly calibrated or has fallen out of calibration.
2 Console has locked up.
3 Touch Screen is defective.
Possible Remedies
1 Recalibrate the P80 screen. See the screen calibration procedure below.
2 Reboot the machine.
3 If the touch screen has failed entirely, console will need to be replaced. This is not a replaceable part.
Screen Calibration Procedure
1 The Welcome screen will be the first screen you see when the P80 console boots up.
2 From the Welcome screen, press the Pause key and continue holding it down while you press in
sequential order an U configuration on the Volume and Channel key pad (
Channel Up, Channel
Down,
Volume Down, Volume Up). Release the Pause key when done pressing the arrows.
3 Touch each + while facing the P80.