ENFORCER V11 PROGRAMMING GUIDE
Text programming
On the system it is possible to label items such as the following:
Zones – Two labels; zone name and location
Area names
Site name
Keypad/reader – Two labels; keypad description and location
Zone and output expander location descriptions
User names
The control panel incorporates a predictive text feature, and works like so:
Enter ‘B’ and ‘Bedroom will be displayed. If the word that is required does not appear, then type the word letter by
letter.
Hint: To type a word, press the relevant button the appropriate number of times – e.g. for the letter ‘k’ press 5 two times, or for the letter ‘s press 7
four times. For punctuation marks, press the 1 button multiple times until the desired character is shown.
Misc button typing
BUTTON TEXT FUNCTION
a
Toggles between upper and lower case characters
b
Moves cursor left
c
Clears letters / adds a space
d
Moves cursor right
[ ]
Moves the cursor left and right
The internal tag reader
The Internal tag reader can be used for arming/disarming, entry control or access control. Refer to the installation
manual for all connections.
Tag area (where a proximity tag/card must be presented to arm/disarm)
Blue LED
Alert
Amber LED
Alarm
Red LED
Tamper
Red LED
Fault
Amber LED
Disarmed
Green LED
The external proximity reader
The external proximity reader can be used for arming/disarming, entry control or access control. Refer to the
installation manual for all connections.
To arm/disarm the system using the external proximity reader, present a pre-
programmed tag to the centre of the unit.
The unit will display the system status:
Green indicates the system is disarmed.
Red indicates the system is armed.
Present the tag again within 10 seconds to arm or disarm the system.
Please note: The system will arm depending on the type of exit mode programmed (nal door, timed or
push to set)

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals