35
ENFORCER V11 PROGRAMMING GUIDE
Replace - battery needs to be replaced immediately.
Wireless Dual Frequency Menu
This option shows information on whether the panel/wireless ZEM are working as a Single or Dual Frequency
system. It will also display which zones (if any) are single frequency and stopping the panel from operating in dual
frequency mode.
Channel
Displays which channel your control panel is operating on (this will be either 01 or 02).
Channel reason
Displays the reason why the panel last switched from one channel to another.
SF/DF status
Displays whether the control panel is currently operating in Single (SF) or Dual (DF) Frequency mode.
Please note: The panel will only operate in dual frequency mode if all peripherals support dual frequency
(having even one SF device will default the whole system into SF mode).
First SF device
Displays the rst single frequency device learnt on to the system (if there is one), once deleted it will display the
next single frequency device and so forth. If there are none it will display; All Devices DF”.
WIRED DEVICES
View Inputs
This option views the status of all wired zones: Open, Close, Tamper, and Fault.
Endstation zones
The status of the zones will be shown. C = Closed. O = Open. F = Fault, T = Tamper.
O - Open
C - Closed
T - Tamper
F - Fault
The resistance reading can also be shown by pressing for any of the above for statuses.
ZEM zones
Choose the ZEM address from [0] to [3] to view the zone status.
View PSUs
This option allows diagnostics of the power supply information for the PSU on the control panel, as well as all the
additional peripheral devices, such as ZEM or output modules that have a PSU on board.
Endstation PSU
End station voltage readings are displayed = Voltage: 13.7V.
ZEM PSUs
Choose the ZEM address from [0] to [3] to read the PSU voltage readings.
OP Mod PSU
Choose the output module address to read the PSU voltage readings.
Keypad Volts
Choose the keypad address from [1] to [3] to read the keypad voltage.
Reader Volts
Choose the reader address from [1] to [3] to read the reader voltage.
COMMUNICATIONS
See the Communications Guide for information regarding the communications and signalling diagnostics.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals