22
ENFORCER V11 PROGRAMMING GUIDE
Set point unsets
An ‘Unset Point’ means that you can program the keypad/reader to unset certain areas only. This is used in
conjunction with the areas allocated to a user code/tag.
For example, if a user code/tag is programmed to operate areas ‘A’ and ‘B’, but the keypad/reader is only
programmed to Unset area ‘A’, then the system will unset area ‘A’ only.
Set point in
The device needs to also be told which Areas it is operating “in”. For example, a keypad may only be needed to
operate in Area A, but other code users may use the keypad to quick arm other Areas (such as a cleaner, director,
caretaker etc). Therefore if Areas A and B are selected in the previous options (Arm point sets and unset), but Area
A only is selected in ‘Set point in’, then Area B will quick arm once a valid tag/code has been entered. To program
Areas operating with their programmed timer, then the Areas need to be entered into the “Set Point In” function.
Set point description
A name and location can be entered here. The name will appear on the display if an alarm has occurred, the
location is used for a more detailed reference if required. E.g. Name = Entrance Keypad. Location = Hall
PROGRAMMING KEYPADS
1. Press b or h to scroll to ‘ASSIGN KEYPADS/READERS’. Press .
2. Press [ or ] to select the address. Press .
3. ‘Type’ will be displayed. Press 0 to select keypad. Press
4. ‘Set Point Sets’ will be displayed. Select the area(s). Press . Set Point
Unsets’ will be displayed. Select the area(s). Press . ‘Set Point In’ will be
displayed. Select the area(s). Press .
5. ‘Set Point Description’ will be displayed. Press to enter the name and
location if required.
6. ‘Enter Name’ will be displayed. Enter the name of the keypad and press .
7. ‘Enter Location’ will be displayed. Enter the location of the keypad and press
.
8. Press [ or ] to select another device address to program (0-3) or press
the h key to return to the Engineer menu
PROGRAMMING READERS
Set Point or Unset Only
1. Press b or h to scroll to ‘ASSIGN KEYPADS/READERS’. Press .
2. Press [ or ] to select the address. Press .
3. ‘Type’ will be displayed. Press 1 to select reader. Press .
4. ‘Reader is’ will be displayed. Press 0 for ‘Set Point’ or press 1 for ‘Unset
Only’ Press .
5. ‘Set Point Sets’ will be displayed. Select the area(s). Press . Set Point
Unsets’ will be displayed. Select the area(s). Press . ‘Set Point In’ will be
displayed. Select the area(s). Press .
6. ‘Set Point Description’ will be displayed. Press to enter the name and
location if required.
7. ‘Enter Name’ will be displayed. Enter the name of the keypad and press .
8. ‘Enter Location’ will be displayed. Enter the location of the keypad and press
.
9. Press [ or ] to select another device address to program (0-3) or press
the h key to return to the Engineer menu.