26
ENFORCER V11 PROGRAMMING GUIDE
Wards/Access
This will only be displayed if an Entry Control or Access Control reader is installed on the system. If the address of
the Entry Control or Access Control device is entered here, then the tag will be assigned to that reader only.
CHANGE ENGINEER CODE
The Engineer code can be 4, 5 or 6 digits long.
CHANGE CODES PROGRAMMING
1. Press b or h to scroll to ‘CODES AND USERS’. Press .
2. ‘5 Digit Pins’ will be displayed. Press [ or ] to enable or disable and
press .
3. ‘Delete Users And Fobs’ will be displayed. Press to delete all the users
from the system or h to move past this option.
4. ‘Change Duress Codes’ will be displayed. Press to add any Duress,
Guard or Dial out codes (as described previously) or press h.
5. ‘Change Master Manager Code’ will be displayed. Press to change the
Master Manager code or press h.
6. ‘Change Engineer Code’ will be displayed. Press to change the
Engineer code or press h to return to the Engineer menu.
VOLUME CONTROL
VOLUME CONTROL?
The Volume Control function applies to the loudspeaker output only. Volume levels at the keypad are
programmed individually in the keypad menu.
The following volume on each sound can be controlled: Entry, Exit, APP Exit, Alarm, Fire, Tamper, Day alarm, and
Chime.
Please note: App exit volume overrides other exit volumes when arming using a smart device application.
Volume levels
0 Completely silent.
1 Silent but sounds a beep when the system is set.
2-7 Volume range, 7 being the loudest.
Code stops sound
If this function is enabled, then once an alarm has been generated (even if the code is not programmed for that
area) the alarm will be silenced, and a ‘Misoperation (Abort) signal’ will be sent. The area will remain armed until a
code or tag is presented that is assigned to that area.
Entry/exit keypads only
If this function is disabled, any entry and exit tones will be heard through the keypad and main sounder. If
enabled, the entry and exit tones will only be heard through the keypad speaker.
Alert kps only
If this function is enabled, any ‘Alert’ tones will be heard on the Keypad only and not the main sounder. If disabled,
the alert tones will heard through both.
Silent technical alert
If this function is enabled then any technical alerts will be silenced, e.g. line fault, ARC call fail.