24
ENFORCER V11 PROGRAMMING GUIDE
Set point in
Enter the areas that the arming station is located in.
Set point description
Enter a name and location for the arming station.
CHANGE TIMERS
CHANGE TIMERS?
This function controls all timers on the system.
COMMONLY USED TIMERS
For a list of all timers, see “Appendix C - Timers” on page 52. Most common programmed timers are:
Entry Time (0-255 seconds)
Conrm Time (1-99 minutes)
Exit Time (0-255 seconds)
Wireless Supervision (0-99 hrs)
Siren Time (2-15 minutes)
App Exit Time (0-199 seconds)
Please note: The timer for zones on ‘Soak Control’ is in the function ‘ENGINEER TESTS’.
OCCUPANCY TIMER AND SUSPEND
This timer and the suspend option both work in conjunction with the zone occupancy attribute and the
programmable occupancy actions when/if the time expires without activation.
Occupancy timer
This timer (set in hours) denes the period of time that any zones with the occupancy attribute enabled must be
trigger in.
Occupancy suspend
Denes the areas which will suspend the timer if armed.
Example
• Zone 1 has the occupancy attribute enabled and is located in area A.
• The occupancy timer is set to 1 hour and occupancy suspend option reads ‘[A ]’ on the screen.
EVENT RESULT
The system is completely disarmed and zone 1 has
not been triggered for 1 hour.
The pre-programmed action is taken.
(External alarm, SMS, keypad etc.)
The system is completely disarmed and zone 1 is
triggered before 1 hour expires.
The 1 hour timer is reset and the zone must be triggered
again within the next hour to prevent action being
taken.
Area A is armed and the zone has not been
triggered for over an hour.
No action. The 1 hour timer will commence when the
system is disarmed.
For occupancy attribute information, see “Input Attributes” on page 17.
To program the actions when the timer expires, see “Occupancy Zones” on page 29.