ENFORCER V11 PROGRAMMING GUIDE
Engineer arm system
Arming and disarming the system can be done using the Engineer code.
1. Press d.
2. Enter the Engineer code (default 1111).
3. Press h if any faults appear.
4. ‘SET SYSTEM?’ is displayed.
5. Press
6. Select the areas to set. Press
7. The arming period will begin.
8. Once the timer expires, and a beep is heard, the area is armed.
9. To disarm, enter the Engineer code again.
Engineer forced arm on inputs
The ‘Force Arm On Inputs’ function enables two nominated zones on the system to be set. Either zone can be
triggered to allow real life signalling or alarm testing. This function is useful when a building is full of people and
these tests are needed.
Please note:
1. The system will give the correct signalling response to the arming, and any resulting alarm.
2. If the system has been armed by any other code, the Engineer code will not disarm it.
1. Press d
2. Enter the Engineer code (default 1111).
3. Press h if any faults appear.
4. ‘SET SYSTEM’ is displayed.
5. Press h
6. ‘FORCE ARM ON 1st INPUT’ is displayed.
7. Enter the 1st zone that is to be active. Press
8. Enter the 2nd zone that is to be active. Press
Please note: If a Final Exit zone is selected, once activated this will start the
entry time and not immediately trigger the alarm.
9. Select the areas to set. Press
10. The arming period will begin
11. Once the timer expires, and a beep is heard, the system is armed and the 2
zones chosen will be active.
12. To unset, enter the Engineer code again.