ENFORCER V11 PROGRAMMING GUIDE
RS485 BUS PROBLEMS
FAULT DESCRIPTION SOLUTION
485 Fail xxx
Device on RS-485 communications bus
is failing to communicate correctly with
the control panel.
Identify device from the location/
name and the device type. Check
device addressed correctly to match
programming. Ensure that 2 devices of
the same type do not share the same
address. Check connections at device,
and cabling to it. If above correct, re-
boot device, followed by re-boot of End
Station.
485/Comms Lost
Displayed on keypad that has not yet
established communications with End
Station
Part of routine initialisation procedure.
If persists, check display at other
keypad(s) to conrm if device failure
at that keypad or complete system
RS-485 failure (temporarily attach
additional keypad direct to End Station
if necessary).
Keypad display is BLANK
Keypad address does not match any
keypad enabled
Check keypad address, noting that a
keypad at address 00 must be present to
program system.
Also check Assigning Keypads menu in
Engineer mode set up correctly.
Keypad display normal,
but KEYS LOCKED OUT
More than one device connected at the
same address
Correct addressing so that no overlaps.
Then power system down and up again
to correctly reinitialise.
Authorisation
Required
The master manager will need to give
the Engineer access
The option Allow Engineer Menu will
need to be enabled by the master
manager
POWER SUPPLY PROBLEMS
FAULT DESCRIPTION SOLUTION
Battery Fault xxx
Battery Fuse failed, OR Battery not
present, OR Battery volts low
Please note: This indication should
be expected during recharge after a
mains failure.
The top line displays ‘Control Panel’ if it
is a fault on the endstation, if the Battery
fault is on a ZEM/OPM xxx will show
the device type and the top line the
location text if entered, if not it shows
xxx-nn where nn is the address of the
ZEM/OPM.
Bat Test Fail XXX Battery Load Test has failed
Only displays if option selected.
Battery uncharged or capacity below
specication may need replacing. Same
method as showing the device as
battery fault.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals