ENFORCER V11 PROGRAMMING GUIDE
Diagnostics
Displays power, zone status, wireless arming stations, wireless signal strength and wireless battery levels.
“Diagnostics” on page 34
Engineer restore options
Congures which events can be reset by the user and which require an engineer.
“Engineer Restore Options” on page 37
Communications
Congures the signalling and smart device control of the system.
“Communications” on page 38
Alarm response
Controls how the system responds in certain situations such as conrmed activations.
“Alarm Response” on page 38
Set up downloading
Allows the system to be accessed remotely via upload/download software.
“Set Up Downloading” on page 41
Dial out menu
Used to dial out to pre-programmed upload/download software PCs.
“Dial Out Menu” on page 42
Software revision
This option identies all software revisions.
“Software Revision” on page 43
Clean start
Wipes all the data from the panel and reverts back to pre-dened factory conguration.
“Clean Start” on page 43
Exit engineer menu
Exits the menu and returns to day mode.
“Exit Engineer Menu” on page 43
GENERAL INFORMATION
Default Codes
Engineers
1111
Master Manager
2222
User
‘Blank’
INITIAL POWER UP
Power up the system and an alarm will be generated. Proceed to the on-board keypad, which will display:
1. Once power has been applied to the system, ‘Please Wait’ will be displayed, followed by ‘485 Comms Lost’. After
approximately 1 minute, the system will display the time (00:00), indicating the system is ready to use.
2. The on-board keypad is defaulted to keypad address ‘0’.
Testing the keypad
With the system disarmed, press the key for 5 seconds at any keypad. This will cause all the LEDs on that
keypad to illuminate, and the LCD screen to display each pixel. The keypad will revert to normal display after the
test which will last about 10 seconds.