EasyManuals Logo
Home>Pyronix>Security System>ENFORCER V11

Pyronix ENFORCER V11 Programming Guide

Pyronix ENFORCER V11
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
40
ENFORCER V11 PROGRAMMING GUIDE
ALARM RESPONSE OPTIONS
Silent 1st Alarm
If this function is selected as conrmed’, then the rst alarm to activate on the system will be silent, but only if
another zone activates (i.e. a conrmed alarm) then the alarm will activate and the alarm tones will be heard. This
option is only valid once the system has been armed for 3 minutes and not if the entry time has started.
Disable Conrm On Entry
To comply with BS8243 clauses 6.4.3 and 6.4.4, this option should be set to YES to disable conrmation once the
entry procedure has started. For use with BS8243 option 6.4.5, this option should be ‘No. If ‘Disable Conrm On
Entry is set to YES this option will disable ALL conrmation signals on entry. If NO the conrmation signals are
enabled on expiry of entry time.
Alarm Starts / Stops (Alarm Responses)
Area # start at
This programs where the alarm response for each area starts.
Area # stop at
This programs where the alarm response for each area escalates to.
The following options have the same start at and ‘stop at’ using the same format at described earlier:
Fire
Gas
PA
Medical
24 Hour
Any Alarms Start
This option allows alarms to start at a dierent place previously programmed if multiple areas are armed.
For example, if 24 hour is programmed to start at internal sounders’ and ‘stop at internal sounders’, this feature is
programming as ‘Internal Sounders’ and the next option has areas A, B and C entered. If A, B and C are armed and
a 24 Hour zone is triggered, the alarm would start with the internal sounders and keypads being audible.
If Areas Armed
Select the areas that the previous option will be applicable to.
Any Alarms Stop
This option allows alarms to stop at a dierent place previously programmed if multiple areas are armed.
For example, if 24 Hour is programmed to ‘Start at keypad and ‘stop at internal sounders’, this feature is
programming as ‘Bells only and the next option has areas A, B and C entered. If A, B and C are armed and a 24
Hour zone is triggered, the alarm would escalate to the external bells.
If Areas Armed
Select the areas that must be armed at the same time for the previous option setting to become active.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals