Chapter 5 Troubleshooting
Tape Drive Error Logs
174 SuperLoader User’s Guide
Table 21 Bugcheck
Log Field Descriptions
Event Error Logs 5 These logs record basic drive events including drive errors, calibration,
and history related actions. There are 14 event error logs, indicated by the
Event number filed is located on the First Line. All Event Error logs
contain the same specialized fields. Figure 105
shows a sample Event
Error log.
Field Description
Event Number: The Event Number is one of the common first line fields explained in the Event
Types sections. Below is a listing of the Bugchecks for each event number.
Number
Description
B810 Library Port Communications problems — Library or Drive Problem. If the
problem continues multiple times after you reset the drive, replace the DCA.
E204 Unexpected Timer 2 Interrupt — Drive or DCA Problem.
EE01 Spurious Non-Askable Interrupt — Drive or DCA Problem.
EE02 Spurious Timer Interrupt — Drive or DCA Problem.
EE03 Spurious Level 5 Interrupt — Drive or DCA Problem.
EE04 Spurious Drive Comm Interrupt — Drive, DCA, or Loader Problem.
EE06 Spurious Diagnostic Comm Interrupt — Drive or DCA Problem.
EE08 Watch Dog Timer Expired — SCSI Bus, Host Controller, Drive, or DCA Problem.
EE09 Spurious Power Fail — Power supply, Power cables, or DCA Problem.
EE0D Spurious Level 6 Interrupt — Drive or DCA Problem.
F202 Loader Time-Out — Loader or DCA Failure.