EasyManuals Logo
Home>Quantum>Storage>Superloader 3

Quantum Superloader 3 User Manual

Quantum Superloader 3
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #252 background imageLoading...
Page #252 background image
Chapter 6 Diagnostics
On-board Remote Management Diagnostic Tests
226 SuperLoader User’s Guide
from 30 seconds to several minutes to complete. The Health Check
test displays an ongoing progress indicator while executing. When
the test completes, either the message
Test Successful appears or the
message
Test Failed and an error code appears. Proceed to step 4.
3 If you are not logged in, you will be asked to enter the Administrator
password. Do the following:
a Enter the administrator password by using the Up and Down
Scroll arrows to select each digit, and press the
Enter key to move
to the next digit. To move to the previous digit, press the
Escape
key. When you have entered the entire 6-digit password, you will
be asked to press the
Enter one more time to submit the
password. If the password is incorrect, you will be asked to re-
enter it using the same procedure. Otherwise, you will be
returned to the Diagnostic Test menu. Press
Enter to run the
desired test.
Running Test appears while the test is running. To
stop the test prematurely, follow the procedure To Perform a
Halt Test from the Front Panel:.
b Each test takes from 30 seconds to several minutes to complete.
The Health Check test displays an ongoing progress indicator
while executing. When the test completes, either the message
Test
Successful
appears or the message Test Failed and an error code
appear. Proceed to step 4
.
4 If the test is successful, press
Enter to return to the Diagnostic test
menu. For detailed results of a test, use On-board Remote
Management to retrieve the Diagnostic test status (see
Troubleshooting
on page 129).
On-board Remote Management Diagnostic Tests 6
Since some of the diagnostic tests require you to insert a cartridge into the
SuperLoader, you cannot perform these tests from a remote location. You
can perform the following diagnostic tests from On-board Remote
Management:
•Halt Test
•Self Test
• Health Check

Table of Contents

Other manuals for Quantum Superloader 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Superloader 3 and is the answer not in the manual?

Quantum Superloader 3 Specifications

General IconGeneral
BrandQuantum
ModelSuperloader 3
CategoryStorage
LanguageEnglish

Related product manuals