Reference Manual V1.19 Software Versions 4.xx
Page 58 003R-682-119
NOTE: These annunciators are shown only when indicator operate in single range
14.5. Setpoint Type (OVER/UNDER) and Hysteresis
Hysteresis defines the amount of weight required for an active setpoint to become inactive again.
For an OVER setpoint it will be the amount the weight must fall below the target to turn off. For an
UNDER setpoint it will be the amount of weight that it goes over the target by for the (already active)
output to turn off. A value of 0 still allows for 0.5 graduations of hysteresis.