www.schaerer.com Troubleshooting
Error messages with fault code
Potential error messages, with a fault code, are shown as pictured in the figure on the left.
Code Designation Cause and effect What to do
2 Brewer motor without
current
Current sensor does not indicate current,
pulse generator does not indicate pulses.
Contact your service partner.
3 Brewer motor pulse
generator: no pulses
Pulse generator not supplying pulses. Cur-
rent sensor indicates traction current.
Faulty pulse generator.
4 Current error, brewer
motor 3
Pulse generator: Pulses are present but the
current sensor does not indicate a current.
5 Brewer motor limit
switch: no signal
The brewer limit switch is not reached, but
current and pulses are OK or the limit switch
does not open.
6 Brewer overcurrent The brewing screen is clogged. Clean the brewing screen.
See "Cleaning" - "Weekly cleaning".
26 Right grinder blocked The grinding fineness setting is too fine.
The fine dust contaminates the mill too quick-
ly.
Set the grind level one level coarser.
See "Service and maintenance" - "Finer set-
ting of grind level".
The grinder is blocked. Contact your service partner.
36 Left grinder blocked The grind level setting is too fine.
The fine dust contaminates the mill too quick-
ly.
Set the grind level one level coarser.
See "Service and maintenance" - "Finer set-
ting of grind level".
The grinder is blocked. Contact your service partner.
87 Boiler sensor breakage Beverage dispensing is not possible. Contact your service partner.
88 Boiler temperature too
high
The water supply is interrupted.
Dispensing of beverages is blocked.
Option 1: With drinking water tank
Check that the drinking water tank is filled
and installed correctly.
Option 2: With mains water supply
Check whether the main water valve is
open.
The brewing unit is blocked.
Dispensing of beverages is blocked.
Clean the brewing unit.
See "Cleaning" - "Weekly cleaning".
The machine is overheated.
Dispensing of beverages is blocked.
Switch off the coffee machine and let it
cool.
Switch the coffee machine back on.
If not rectified, contact your service part-
ner.
89 Boiler heating time er-
ror
Fault while heating Switch the machine off and back on.
130 General current error Current consumption of power supply when
switching on is too high.
Contact your service partner.
149 Boiler heating time er-
ror
Current consumption with 24 V/30 V power
supply is too high.
157 Boiler heating time er-
ror
The battery is almost empty. The PC board
fails when the battery is fully empty.
BA SCV_EN
V06 | 11.2015
88

Table of Contents

Other manuals for Schaerer Vito

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaerer Vito and is the answer not in the manual?

Schaerer Vito Specifications

General IconGeneral
BrandSchaerer
ModelVito
CategoryCoffee Maker
LanguageEnglish

Related product manuals