Chapter 6 Operating Instructions
DME4000
100 © SICK AG • Germany • Subject to change without notice 8014584/ZN33/2017-07
Specifications
6.4 Specifications DME4000-1xx
DME4000-
111
112
113
114
115
117
119
Part no.
1029789
1029788
1029796
1029800
1029801
1029807
1042838
Measurement range
0.15 … 50 mm
Accuracy
± 3 mm
Reproducibility
1)
1 mm
Measurement value output
1 ms
2 ms
2 ms
2 ms
2 ms
2 ms
4 ms
Resolution (adjustable)
0.05 … 5 mm
Temperature drift (type)
0.1 mm/K
Temperature influence
1 ppm/K
Air pressure influence
0.3 ppm/hPa
Initialization time
500 ms
900 ms
500 ms
Max. movement speed
10 m/s
Supply voltage V
S
2)
18 … 30 V DC
Residual ripple
3)
5 V
PP
Current consumption (without
heating)
< 250 mA at 24 V DC
Optical transmitter
Laser diode (red light)
Laser class
2 (EN 60825-1/C.D.R.H.)
Operating life (at 25 °C)
MTTF 50,000 h
Light spot diameter/distance
max. 100 mm/50 m
Switching outputs MF1, MF2
B (push/pull)
Output (MF1/MF2)
HIGH: V
S
< 3 V; LOW < 2 V
Input (MF1)
4)
HIGH: > 12 V; LOW < 3 V
Output current
5)
100 mA (short-circuit protected, overload-protected)
Interfaces
SSI
PROFIBUS
12 MBd
RS 422
DeviceNet 500 kBd
Hiperface
CANopen
Ambient operating temperature
10 … +55 °C
Storage temperature
25 … +75 °C
DME4000 heating
121
122
123
124
Not
available
127
Part no.
1029792
1029793
1029797
1029808
1029812
Ambient operating temperature
40 … +55 °C
Current consumption
(with heating)
< 1000 mA
Enclosure rating
IP 65
Electric protection class
VDE class 2 (rated voltage 32 V)
EMC
EN 61000-6-2, EN 55011: class B
Mechanical load
Shock: EN 600 68-2-27/-2-29, Sinus: EN 600 68-2-6, noise: EN 600 68-2-64
Weight
Approx. 1650 g
1)
Statistical error, constant ambient conditions, minimum switch-on time 10 min
2)
Reverse-polarity protected
3)
May not exceed or fall short of V
S
tolerances
4)
Not reverse-polarity protected
5)
Max. 100 nF/20 mH